1.5 Motion Sensor MS-100 (Option)
The MS-100 measures ship’s pitching and rolling angles with sensors using the
principles of the gyroscope. The MS-100 is free from error caused by ship’s ver-
tical and horizontal motion. Therefore, it can be installed at any convenient loca-
tion. However, ship’s semi-permanent inclination due to loading imbalance cannot
be detected. Compensate for this as described in Chapter 3.
Mounting considerations
Vibration in the mounting area should be
minimal.
• Locate the unit away from areas subject
to water splash.
• The ambient temperature should not ex-
ceed 50°C.
Mounting procedure
Orient the FORE mark on the unit toward the ship’s bow and mount the unit level
to within 5° in all directions.
1.6 External Interface (Option)
This section shows how to install External E/S Interface (type OP06-13) and/or
the External Monitor Interface (type OP06-14).
For connecting external monitor, prepare mini D-SUB 15 pin cable (male-male).
Recommended cable : EVNPSO5-50ft, manufactured by Black Box Japan Co.,Ltd.
External monitor interface installation kit
traPyt'Q,epyT.oNedoCyt'Q
.yssAecafretnIrotinoMlanretxE--1
.yssArotcennoCHX)P31-31(313-60048-055-6001
wercS6x3M301-188-0004
wercS8x3M404-188-0001
seiTelbaC942.oN178-515-0001
FORE
AFT
θ ≤ 5°
Figure 1-18 Motion sensor MS-100